A cold start of the AMC-IP board will delete all previous
 
A cold start of the AMC-IP board will delete all previous
programming, load the default database and set the default IPaddress
+
programming, load factory default settings and set the default IP-address
 
to 169.254.1.5 with mask 255.255.0.0 on Eth0.
 
to 169.254.1.5 with mask 255.255.0.0 on Eth0.
See section 2.4 for factory default settings.
 
  
 
===Cold start procedure===
 
===Cold start procedure===

Revision as of 11:01, 15 August 2007

Perform Cold Start

A cold start of the AMC-IP board will delete all previous programming, load factory default settings and set the default IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.

Cold start procedure

Cold start to load default database
  • Turn the exchange mains switch ON (on the back of the

cabinet).

  • Hold the cold start button on the AMC-IP board depressed.
  • Press the reset button on the APC card briefly.

(On the E7 exchange, the reset button is located on the power card.)

  • Keep the cold start button pressed at least 1 sec. after reset.

The AMC status LED will blink green when the boot is ready.

Cold-start of AMC application only, keep IP setting

Cold Start of AMC-IP.2.jpg
  • Press the reset button on the APC card briefly.

(On the E7 exchange, the reset button is located on the power card.)

  • After 10 sec., press the cold start button on the AMC-IP board.
  • Keep cold start button pressed until AMC running LED is

blinking green.

Modify Factory Default Settings

The system is set up with a default program and is working without any further programming. To change or add to the default settings, the AlphaPro programming tool must be used.

The default parameters are restored after auto-load by performing a cold start, see section 2.3.

To modify factory default settings, see chapter 4.