Difference between revisions of "Cold Start of AMC-IP"
From Zenitel Wiki
(→Cold-start of AMC application only, keep IP setting) |
|||
Line 11: | Line 11: | ||
=== Cold-start of AMC application only, keep IP setting === | === Cold-start of AMC application only, keep IP setting === | ||
− | [[Image:Cold Start of AMC-IP.2.jpg|right|150px|thumb]] | + | [[Image:Cold Start of AMC-IP.2.jpg|right|150px|thumb|Cold-start of AMC application]] |
*Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.) | *Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.) | ||
*After 10 sec., press the cold start button on the AMC-IP board. | *After 10 sec., press the cold start button on the AMC-IP board. |
Revision as of 13:07, 15 August 2007
Performing a cold start of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.
Cold start procedure
- Turn the exchange mains switch ON (on the back of the cabinet).
- Hold the cold start button on the AMC-IP board depressed.
- Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
- Keep the cold start button pressed at least 1 sec. after reset. The AMC status LED will blink green when the boot is ready.
<br\><br\><br\><br\><br\><br\>
Cold-start of AMC application only, keep IP setting
- Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
- After 10 sec., press the cold start button on the AMC-IP board.
- Keep cold start button pressed until AMC running LED is blinking green.
Modify Factory Default Settings
After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the AlphaPro programming tool must be used.