===Cold start procedure===
 
===Cold start procedure===
[[Image:Cold Start of AMC-IP.jpg|right|150px|thumb|Cold start to load default database]]
+
[[Image:Cold Start of AMC-IP.jpg|right|100px|thumb|Cold start to load default factory settings]]
 
*Turn the exchange mains switch ON (on the back of the cabinet).
 
*Turn the exchange mains switch ON (on the back of the cabinet).
 
*Hold the [[AMC-IP#LED indicators|cold start button]] on the [[AMC-IP]] board depressed.
 
*Hold the [[AMC-IP#LED indicators|cold start button]] on the [[AMC-IP]] board depressed.

Revision as of 13:08, 15 August 2007

Performing a cold start of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.

Cold start procedure

Cold start to load default factory settings
  • Turn the exchange mains switch ON (on the back of the cabinet).
  • Hold the cold start button on the AMC-IP board depressed.
  • Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
  • Keep the cold start button pressed at least 1 sec. after reset. The AMC status LED will blink green when the boot is ready.

Cold-start of AMC application only, keep IP setting

Cold-start of AMC application
  • Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
  • After 10 sec., press the cold start button on the AMC-IP board.
  • Keep cold start button pressed until AMC running LED is blinking green.

Modify Factory Default Settings

After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the AlphaPro programming tool must be used.