== Station LED (on board and in front plate) ==
== Station LED (on board and in front plate) ==
Blinking 1 sec. interval Station does not have connection to the AlphaCom E exchange.
'''Blinking 1 sec. interval''': Station does not have connection to the AlphaCom E exchange.
Possible reasons:  
''Possible reasons'':  
- No connection to Ethernet  
* No connection to Ethernet  
- Wrong AlphaCom E IP address configured  
* Wrong AlphaCom E IP address configured  
- Invalid IP address  
* Invalid IP address  
- No or wrong gateway to the AlphaCom E exchange  
* No or wrong gateway to the AlphaCom E exchange
Blinking 5 sec. interval Station has connection to the AlphaCom E exchange, but has not  
been registered.  
'''Blinking 5 sec. interval''': Station has connection to the AlphaCom E exchange, but has not been registered.  
Reason:  
''Reason'':  
- Station has not been programmed in AlphaPro  
* Station has not been programmed in AlphaPro  
No blinking  
 
Possible reasons:  
'''No blinking'''
- Station connected and registered to the AlphaCom E exchange - All OK  
''Possible reasons'':  
- Station not powered up (if no other LEDs are active)
* Station connected and registered to the AlphaCom E exchange - All OK  
* Station not powered up (if no other LEDs are active)


== Status LED ==
== Status LED ==

Revision as of 21:33, 10 October 2007

IP Substation Connections

Station LED (on board and in front plate)

Blinking 1 sec. interval: Station does not have connection to the AlphaCom E exchange. Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom E IP address configured
  • Invalid IP address
  • No or wrong gateway to the AlphaCom E exchange

Blinking 5 sec. interval: Station has connection to the AlphaCom E exchange, but has not been registered. Reason:

  • Station has not been programmed in AlphaPro

No blinking Possible reasons:

  • Station connected and registered to the AlphaCom E exchange - All OK
  • Station not powered up (if no other LEDs are active)

Status LED

Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been registered Blinking 3 green Station connected and registered in the AlphaCom E exchange LAN LEDs (on LAN and AUX RJ45-jacks): Left green LED: - Steady light Ethernet connection OK - Blinking Ethernet traffic - No light No Ethernet connection Right amber LED: - Light 100 Mbit Ethernet connection - No light 10 Mbit Ethernet connection