Indication LEDs
#REDIRECT [[Weather and Vandal Resistant IP Substation - 1008041100]]
STATION LED (on board and in front plate)
Blinking 1 sec. interval Station does not have connection to the AlphaCom E exchange.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom E IP address configured
- Invalid IP address
- No or wrong gateway to the AlphaCom E exchange
Blinking 5 sec. interval Station has connection to the AlphaCom E exchange, but has not
been registered.
Reason:
- Station has not been programmed in AlphaPro
No blinking
Possible reasons:
- Station connected and registered to the AlphaCom E exchange - All OK
- Station not powered up (if no other LEDs are active)
STATUS LED
Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange
Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been
registered
Blinking 3 green Station connected and registered in the AlphaCom E exchange
LAN LEDs (on LAN and AUX RJ45-jacks):
Left green LED:
- Steady light Ethernet connection OK
- Blinking Ethernet traffic
- No light No Ethernet connection
Right amber LED:
- Light 100 Mbit Ethernet connection
- No light 10 Mbit Ethernet connection