| Indication LEDs
| | #REDIRECT [[Weather and Vandal Resistant IP Substation - 1008041100]] |
| STATION LED (on board and in front plate)
| |
| Blinking 1 sec. interval Station does not have connection to the AlphaCom E exchange.
| |
| Possible reasons:
| |
| - No connection to Ethernet
| |
| - Wrong AlphaCom E IP address configured
| |
| - Invalid IP address
| |
| - No or wrong gateway to the AlphaCom E exchange
| |
| Blinking 5 sec. interval Station has connection to the AlphaCom E exchange, but has not
| |
| been registered.
| |
| Reason:
| |
| - Station has not been programmed in AlphaPro
| |
| No blinking
| |
| Possible reasons:
| |
| - Station connected and registered to the AlphaCom E exchange - All OK
| |
| - Station not powered up (if no other LEDs are active)
| |
| STATUS LED
| |
| Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange
| |
| Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been
| |
| registered
| |
| Blinking 3 green Station connected and registered in the AlphaCom E exchange
| |
| LAN LEDs (on LAN and AUX RJ45-jacks):
| |
| Left green LED:
| |
| - Steady light Ethernet connection OK
| |
| - Blinking Ethernet traffic
| |
| - No light No Ethernet connection
| |
| Right amber LED:
| |
| - Light 100 Mbit Ethernet connection
| |
| - No light 10 Mbit Ethernet connection | |
| | |