Actions

IP Substation Indication LEDs: Difference between revisions

From Zenitel Wiki

No edit summary
 
(4 intermediate revisions by one other user not shown)
Line 1: Line 1:
[[Image:IP substation connections.jpg|280px|right|IP Substation Connections]]
#REDIRECT [[Weather and Vandal Resistant IP Substation - 1008041100]]
== Station LED (on board and in front plate) ==
'''Blinking at 1 second interval''': Station does not have connection to the AlphaCom E exchange.
:''Possible reasons'':
:* No connection to Ethernet
:* Wrong AlphaCom E IP address configured
:* Invalid IP address
:* No or wrong gateway to the AlphaCom E exchange
'''Blinking at 5 seconds interval''': Station has connection to the AlphaCom E exchange, but has not been registered.
:''Reason'':
:* Station has not been programmed in AlphaPro
 
'''No blinking'''
:''Possible reasons'':
:* Station connected and registered to the AlphaCom E exchange - All OK
:* Station not powered up (if no other LEDs are active)
 
== Status LED ==
'''Blinking 2 red + 1 green''': Station does not have connection to the AlphaCom E exchange
'''Blinking 1 red + 2 green''':Station has connection to AlphaCom E exchange, but has not been registered
'''Blinking 3 green''': Station connected and registered in the AlphaCom E exchange
 
== LAN LEDs (on LAN and AUX RJ45-jacks) ==
'''Left green LED''':
* Steady light Ethernet connection OK
* Blinking Ethernet traffic
* No light No Ethernet connection
'''Right amber LED''':
* Light 100 Mbit Ethernet connection
* No light 10 Mbit Ethernet connection
 