Difference between revisions of "AMC Unit numbers"
From Zenitel Wiki
Line 1: | Line 1: | ||
+ | Table 1: Normal (Compact) Unit Numbers | ||
+ | {| border="1" | ||
+ | |- | ||
+ | !IC/DC !! In/Out !!Unit Number !!BP msg repr.!! # units !! | ||
+ | |- | ||
+ | |IC || Out ||00h–1Fh ||00h–1Fh ||32 ||Output Resource Units connected to Channels 0…31, respectively | ||
+ | |- | ||
+ | |IC || Out ||20h–2Fh ||20h–2Fh ||16 ||Output Resource Units not connected to Channels | ||
+ | |- | ||
+ | |IC || Out ||30h–37h ||30h–37h || 8 ||Output Resource Broadcast Classes (from top) | ||
+ | |- | ||
+ | |IC || Out ||38h–3Bh ||38h–3Bh || 4 ||Output Resource Units with Fixed U# Mapping | ||
+ | |- | ||
+ | |IC || Out || — ||3Ch–3Fh || 4 ||—reserved for extended Adressing prefixes— | ||
+ | |- | ||
+ | |IC || In ||40h–5Fh ||40h–5Fh ||32 ||Input Resource Units connected to Channels 0…31, respectively | ||
+ | |- | ||
+ | |IC || In ||60h–6Fh ||60h–6Fh ||16 ||Input Resource Units not connected to Channels | ||
+ | |- | ||
+ | |IC || In ||70h–77h ||70h–77h || 8 ||Input Resource Broadcast Classes (from top) | ||
+ | |- | ||
+ | |IC || In ||78h–3Bh ||78h–7Bh || 4 ||Input Resource Units with Fixed U# Mapping | ||
+ | |- | ||
+ | |IC || In || — ||7Ch–7Fh || 4 ||—reserved for extended Adressing prefixes— | ||
+ | |- | ||
+ | |DC || Out ||80h–9Fh ||80h–9Fh ||32 ||Direct Control of Output Part of Channels 0…31, respectively | ||
+ | |- | ||
+ | |DC || Out ||A0h–AFh ||A0h–AFh ||16 ||Output Res. Units connected to or being Direct Remote Control Outputs 0…15, respectively | ||
+ | |- | ||
+ | |DC || Out ||B0h–B7h ||B0h–B7h || 8 ||Output Res. Units connected to or being Direct Remote Control Outputs 64…71, respectively | ||
+ | |- | ||
+ | |DC || Out ||B8h–BBh ||B8h–BBh || 4 ||Output Resource Units with Fixed U# Mapping | ||
+ | |- | ||
+ | |DC || Out ||— ||BCh–BFh || 4 ||—reserved for extended Adressing prefixes— | ||
+ | |- | ||
+ | |DC || In ||C0h–DFh ||C0h–DFh ||32 ||Direct Control of Input Part of Channels 0…31, respectively | ||
+ | |- | ||
+ | |DC || In ||E0h–EFh ||E0h–EFh ||16 ||Input Res. Units connected to or being Direct Remote Control Inputs 0…15, respectively | ||
+ | |- | ||
+ | |DC || In ||F0h–F7h ||F0h–F7h || 8 ||Input Res. Units connected to or being Direct Remote Control Inputs 64…71, respectively | ||
+ | |- | ||
+ | |DC || In ||F8h–FBh ||F8h–FBh || 4 ||Input Resource Units with Fixed U# Mapping | ||
+ | |- | ||
+ | |DC || In || — ||FCh–FFh || 4 ||—reserved for extended Adressing prefixes— | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
Table 2: Extended Unit Numbers | Table 2: Extended Unit Numbers | ||
Revision as of 13:02, 28 January 2008
Table 1: Normal (Compact) Unit Numbers
IC/DC | In/Out | Unit Number | BP msg repr. | # units | |
---|---|---|---|---|---|
IC | Out | 00h–1Fh | 00h–1Fh | 32 | Output Resource Units connected to Channels 0…31, respectively |
IC | Out | 20h–2Fh | 20h–2Fh | 16 | Output Resource Units not connected to Channels |
IC | Out | 30h–37h | 30h–37h | 8 | Output Resource Broadcast Classes (from top) |
IC | Out | 38h–3Bh | 38h–3Bh | 4 | Output Resource Units with Fixed U# Mapping |
IC | Out | — | 3Ch–3Fh | 4 | —reserved for extended Adressing prefixes— |
IC | In | 40h–5Fh | 40h–5Fh | 32 | Input Resource Units connected to Channels 0…31, respectively |
IC | In | 60h–6Fh | 60h–6Fh | 16 | Input Resource Units not connected to Channels |
IC | In | 70h–77h | 70h–77h | 8 | Input Resource Broadcast Classes (from top) |
IC | In | 78h–3Bh | 78h–7Bh | 4 | Input Resource Units with Fixed U# Mapping |
IC | In | — | 7Ch–7Fh | 4 | —reserved for extended Adressing prefixes— |
DC | Out | 80h–9Fh | 80h–9Fh | 32 | Direct Control of Output Part of Channels 0…31, respectively |
DC | Out | A0h–AFh | A0h–AFh | 16 | Output Res. Units connected to or being Direct Remote Control Outputs 0…15, respectively |
DC | Out | B0h–B7h | B0h–B7h | 8 | Output Res. Units connected to or being Direct Remote Control Outputs 64…71, respectively |
DC | Out | B8h–BBh | B8h–BBh | 4 | Output Resource Units with Fixed U# Mapping |
DC | Out | — | BCh–BFh | 4 | —reserved for extended Adressing prefixes— |
DC | In | C0h–DFh | C0h–DFh | 32 | Direct Control of Input Part of Channels 0…31, respectively |
DC | In | E0h–EFh | E0h–EFh | 16 | Input Res. Units connected to or being Direct Remote Control Inputs 0…15, respectively |
DC | In | F0h–F7h | F0h–F7h | 8 | Input Res. Units connected to or being Direct Remote Control Inputs 64…71, respectively |
DC | In | F8h–FBh | F8h–FBh | 4 | Input Resource Units with Fixed U# Mapping |
DC | In | — | FCh–FFh | 4 | —reserved for extended Adressing prefixes— |
Table 2: Extended Unit Numbers
IC/DC | In/Out | Unit Number | BP msg repr. | # units | |
---|---|---|---|---|---|
IC | Out | 100h–11Fh | 3D00h–3D1Fh | 32 | Output Resource Units connected to Channels 32…63, respectively |
IC | Out | 120h–16Fh | 3D20h–3D6Fh | 80 | More Output Resource Units not connected to Channels |
IC | Out | 170h–17Fh | 3D70h–3D7Fh | 16 | More Output Resource Units not connected to Channels |
IC | In | 180h–19Fh | 7D00h–7D1Fh | 32 | Input Resource Units connected to Channels 32…63, respectively |
IC | In | 1A0h–1EFh | 7D20h–7DEFh | 80 | More Input Resource Units not connected to Channels |
IC | In | 1F0h–1FFh | 7DF0h–7D7Fh | 16 | More Input Resource Units not connected to Channels |
DC | Out | 200h–21Fh | BD00h–BD1Fh | 32 | Direct Control of Output Part of Channels 32…63, respectively |
DC | Out | 220h–24Fh | BD20h–BD4Fh | 48 | Output Resource Units connected to or being Direct Remote Control Outputs 16…63, respectively |
DC | Out | 250h–257h | BD50h–BD57h | 8 | Output Resource Units with Fixed U# Mapping. |
DC | Out | 258h–27Fh | BD58h–BD7Fh | 40 | —Reserved for future use— |
DC | In | 280h–29Fh | FD00h–FD1Fh | 32 | Direct Control of Input Part of Channels 32…63, respectively |
DC | In | 2A0h–2CFh | FD20h–FD4Fh | 48 | Input Resources connected to or being Direct Remote Control Inputs 16…63, respectively |
DC | In | 2D0h–2D7h | FD50h–FD57h | 8 | Input Resource Units with Fixed U# Mapping. |
DC | In | 2D8h–2FFh | FD58h–FD7Fh | 40 | —Reserved for future use— |
- IC
- Indirect Control, via backplane message
- DC
- Direct Control, memory write to SBI