Difference between revisions of "Play DAK Feature"
From Zenitel Wiki
(→Programming of DAK sequences with single digit dialing and wait states) |
(→Programming of DAK sequences with single digit dialing and wait states) |
||
Line 37: | Line 37: | ||
− | If longer strings are needed the DAK_AS_RCI event trigger can be used for sending the play dak $PD data protocol | + | If longer strings are needed the DAK_AS_RCI event trigger can be used for sending the play dak [[PLAY_DAK |$PD]] data protocol message. |
− | + | ||
A description of "first" edition of the Play DAK function from 10x43x520 is found here: | A description of "first" edition of the Play DAK function from 10x43x520 is found here: | ||
[[Play DAK | Play DAK - "Old version" only on 10x43x520]] | [[Play DAK | Play DAK - "Old version" only on 10x43x520]] |
Revision as of 07:12, 10 June 2008
Programming of DAK sequences with single digit dialing and wait states
Available from amcd 1043x0521
By using the DAK "T" parameter a 18 digit string can be programmed.
Sequence syntax:
0-9 Digits # * Signaling available during trunk connection w Pause for 0,5 Second W Pause for 1 Second
Example DAK string as programmed in AlphaPro: <br\>
Description: <br\> Get line out "01" <br\> Wait 1 Sec <br\> Dial Tellog pin code "123#"<br\> Wait 2 Sec <br\> Dial Zenitel "40002500". <br\>
Default digit step time is 200 ms. Configurable from NVRAM:
85 &000874 .ex_profile.timeouts.play_dak_time = 2 (0x0002) <br\>
If longer strings are needed the DAK_AS_RCI event trigger can be used for sending the play dak $PD data protocol message.
A description of "first" edition of the Play DAK function from 10x43x520 is found here:
Play DAK - "Old version" only on 10x43x520