Actions

Difference between revisions of "Play DAK Feature"

From Zenitel Wiki

(Restriction)
(No difference)

Revision as of 10:16, 13 October 2009

Programming of DAK sequences with single digit dialing and wait states

Available from AMC 10.50

Play DAK programmed from DAK string

By using the DAK "T" parameter a 18 digit string can be programmed.

Sequence syntax:

0-9    Digits
# *    Signaling available during trunk connection
w      Pause for 0,5 Second 
W      Pause for 1 Second 

Example DAK string as programmed in AlphaPro: <br\> AlphaPro Play DAK


Description: <br\> Get line out "01" <br\> Wait 1 Sec <br\> Dial Tellog pin code "123#"<br\> Wait 2 Sec <br\> Dial Zenitel "40002500". <br\>

Timing of play speed

Default digit step time is 200 ms. Configurable from NVRAM:

85 &000874 .ex_profile.timeouts.play_dak_time = 2 (0x0002) <br\>


Play DAK by Data Protocol

If longer strings are needed the Station DAK key as RCI event trigger can be used for sending the play dak $PD data protocol message.

Restriction

Maximum 50 simultaneous DAK Play functions can be activated at the same time in one node.