Difference between revisions of "RingMaster CB901"
From Zenitel Wiki
(New page: Tekst) |
|||
Line 1: | Line 1: | ||
− | + | ==SYSTEM BUILD-UP== | |
+ | ===General Description=== | ||
+ | An existing Ring-Master CB901 system can be expanded by adding one | ||
+ | or more STENTOFON AlphaCom E exchanges. The two systems are | ||
+ | interconnected via data and audio links. Stations and equipment in both | ||
+ | systems will interact as part of the same system. The AlphaCom E IP | ||
+ | services can be accessed from the Ring-Master system. | ||
+ | |||
+ | '''Data''' | ||
+ | <br> | ||
+ | Data are transmitted via one or two serial RS232 links. | ||
+ | * One link (ETP, External Trunk Protocol) is used for station-tostation | ||
+ | calls, Group Call, Call Request and Caller ID. | ||
+ | * An optional link (SIO, Serial Input Output) is used for other | ||
+ | functions like Privacy information and Call Request camp on. | ||
+ | <br> | ||
+ | <br> | ||
+ | '''Audio''' | ||
+ | <br> | ||
+ | The audio interconnection between CB901 and AlphaCom E is | ||
+ | analogue. | ||
+ | * There are 6 conversation channels in a 12 pair twisted cable | ||
+ | between each Interlink B board in CB901 and AGA board(s) in | ||
+ | AlphaCom E. | ||
+ | <br> | ||
+ | <br> | ||
+ | '''Audio switching control (Duplex)''' | ||
+ | <br> | ||
+ | <br> | ||
+ | There is no transfer of switching control signals between the CB901 and | ||
+ | AlphaCom E. The switching will take place individually in the Ring- | ||
+ | Master station and in AlphaCom E. | ||
+ | Programming | ||
+ | The CB901-AlphaCom E interface features are programmed by use of: | ||
+ | * SVT for the CB901 part | ||
+ | * AlphaPro and AlphaWeb for the AlphaCom E part and the Ring- | ||
+ | Master Daemon |
Revision as of 09:07, 28 July 2008
SYSTEM BUILD-UP
General Description
An existing Ring-Master CB901 system can be expanded by adding one or more STENTOFON AlphaCom E exchanges. The two systems are interconnected via data and audio links. Stations and equipment in both systems will interact as part of the same system. The AlphaCom E IP services can be accessed from the Ring-Master system.
Data
Data are transmitted via one or two serial RS232 links.
- One link (ETP, External Trunk Protocol) is used for station-tostation
calls, Group Call, Call Request and Caller ID.
- An optional link (SIO, Serial Input Output) is used for other
functions like Privacy information and Call Request camp on.
Audio
The audio interconnection between CB901 and AlphaCom E is
analogue.
- There are 6 conversation channels in a 12 pair twisted cable
between each Interlink B board in CB901 and AGA board(s) in
AlphaCom E.
Audio switching control (Duplex)
There is no transfer of switching control signals between the CB901 and
AlphaCom E. The switching will take place individually in the Ring-
Master station and in AlphaCom E.
Programming
The CB901-AlphaCom E interface features are programmed by use of:
- SVT for the CB901 part
- AlphaPro and AlphaWeb for the AlphaCom E part and the Ring-
Master Daemon