This article describers all Turbine Compact Analog Standard Station connections.
[[File:TCAS Connections 1.PNG|thumb|right500px|TCAS substation - Rear side]]
This article describes connection details of the analog intercoms [[TCAS-1]], [[TCAS-2]] and [[TCAS-3]].


The Turbine analog station has an RJ-45 port and 6 external connectors.
==Wiring==
The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:
* 0.5 mm wires: 1.4 km
* 0.6 mm wires: 2.0 km
* 0.9 mm wires: 4.0 km


{|border="1"
The station line can be connected in to ways: 
|Power || Draws power from AlphaCom signal line
* By means of an RJ45 connector at the rear side of the station, or
|-
* By using the plugable screw connector
|RJ-45 port || AlphaCom connection
|-
|A, B, C, D wires || AlphaCom connection when RJ-45 port is not used
|-
|}


'''Note!''' Use cables crimped with ferrules for terminal block connectors
Connection using the RJ45 connector:
[[File:WiringAnalogTCAS.png|thumb|left|800px]]
<br style="clear:both;" />


To set up the analog station as an intercom:
{{note| The [[Station cable for 4 wire analogue station|station cable]] is not a 1:1 cable! }}
:1.  Connect the RJ-45 port on the station to the AlphaCom exchange
 
:2.  Register the station in the AlphaCom exchange
For details on connection at the AlphaCom server side, see [[ASLT - AlphaCom Subscriber Line Board]]
<br style="clear:both;" />


==Second Call Key==
<br>
The station is prepared for a future second call key (DAK2).


This second call key can be found on the print if wanted and utilized with an external call button.
== Second Call Button ==
The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above).  
[[File:TCAS Connections 2.PNG|thumb|left|500px]]
[[File:TCAS Connections 2.PNG|thumb|left|500px]]
<br style="clear:both;" />
<br style="clear:both;" />
* A second external call key must be connected between the A-wire and the lower leg on D6 (highlighted in the image above).


[[Category: Turbine]]
[[Category: Turbine Connections]]

Latest revision as of 11:51, 31 August 2018

AlphaCom icon 300px.png
TCAS substation - Rear side

This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.

Wiring

The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:

  • 0.5 mm wires: 1.4 km
  • 0.6 mm wires: 2.0 km
  • 0.9 mm wires: 4.0 km

The station line can be connected in to ways:

  • By means of an RJ45 connector at the rear side of the station, or
  • By using the plugable screw connector

Connection using the RJ45 connector:

WiringAnalogTCAS.png


Note icon The station cable is not a 1:1 cable!


For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board


Second Call Button

The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above).

TCAS Connections 2.PNG


MediaWiki spam blocked by CleanTalk.