Actions

Difference between revisions of "TCAS Connections"

From Zenitel Wiki

(Second Call Button)
 
(18 intermediate revisions by 2 users not shown)
Line 1: Line 1:
[[File:TCAS Connections 1.PNG|right]]
+
{{A}}
This article describers all Turbine Compact Analog Standard Station connections.
+
[[File:TCAS Connections 1.PNG|thumb|right500px|TCAS substation - Rear side]]
 +
This article describes connection details of the analog intercoms [[TCAS-1]], [[TCAS-2]] and [[TCAS-3]].
  
The Turbine analog station has an RJ-45 port and 6 external connectors.
+
==Wiring==
 +
The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:
 +
* 0.5 mm wires: 1.4 km
 +
* 0.6 mm wires: 2.0 km
 +
* 0.9 mm wires: 4.0 km
  
{|border="1"
+
The station line can be connected in to ways: 
|Power || Draws power from AlphaCom signal line
+
* By means of an RJ45 connector at the rear side of the station, or
|-
+
* By using the plugable screw connector
|RJ-45 port || AlphaCom connection
 
|-
 
|A, B, C, D wires || AlphaCom connection when RJ-45 port is not used
 
|-
 
|}
 
  
'''Note!''' Use cables crimped with ferrules for terminal block connectors
+
Connection using the RJ45 connector:
 +
[[File:WiringAnalogTCAS.png|thumb|left|800px]]
 +
<br style="clear:both;" />
  
To set up the analog station as an intercom:
+
{{note| The [[Station cable for 4 wire analogue station|station cable]] is not a 1:1 cable! }}
:1.  Connect the RJ-45 port on the station to the AlphaCom exchange
+
 
:2.  Register the station in the AlphaCom exchange
+
For details on connection at the AlphaCom server side, see [[ASLT - AlphaCom Subscriber Line Board]]
<br style="clear:both;" />
 
  
==Second Call Key==
+
<br>
The station is prepared for a future second call key (DAK2).
 
  
This second call key can be found on the print if wanted and utilized with an external call button.
+
== Second Call Button ==
 +
The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above).  
 
[[File:TCAS Connections 2.PNG|thumb|left|500px]]
 
[[File:TCAS Connections 2.PNG|thumb|left|500px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
* A second external call key must be connected between the A-wire and the lower leg on D6 (highlighted in the image above).
 
  
 
[[Category: Turbine Connections]]
 
[[Category: Turbine Connections]]

Latest revision as of 11:51, 31 August 2018

AlphaCom icon 300px.png
TCAS substation - Rear side

This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.

Wiring

The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:

  • 0.5 mm wires: 1.4 km
  • 0.6 mm wires: 2.0 km
  • 0.9 mm wires: 4.0 km

The station line can be connected in to ways:

  • By means of an RJ45 connector at the rear side of the station, or
  • By using the plugable screw connector

Connection using the RJ45 connector:

WiringAnalogTCAS.png


Note icon The station cable is not a 1:1 cable!


For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board


Second Call Button

The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above).

TCAS Connections 2.PNG