[[File:2-2d exercise.PNG|left|thumb|500px|System configuration]] | [[File:2-2d exercise.PNG|left|thumb|500px|System configuration]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
Line 41: | Line 40: | ||
Program DAK 1 and DAK 2 of the Control Room station with the codes for Call Forwarding on (9533) and Call Forwarding off (9534), and add an appropriate display text. | Program DAK 1 and DAK 2 of the Control Room station with the codes for Call Forwarding on (9533) and Call Forwarding off (9534), and add an appropriate display text. | ||
− | [[File:2-2d solution5.PNG|left|thumb|500px|Select the '''Control Room''' station in the list box, press '''DAK''' button, select the "''' | + | [[File:2-2d solution5.PNG|left|thumb|500px|Select the '''Control Room''' station in the list box, press '''DAK''' button, select the "'''DAK 1-10'''" tab, and on DAK key 1 and 2 enter 9533 T <text> and 9534 T <text>.]] |
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
+ | |||
+ | '''Verify that:''' | ||
+ | * Call Forwarding is turned on and off | ||
+ | * RCO 3 is turned on and off | ||
+ | * The Call forwarding on/off is logged in the "System Log" (AlphaWeb: System Monitoring -> Logging. It might be that logging has to be enabled first: System Configuration -> Logging). | ||
Line 53: | Line 57: | ||
===Related articles === | ===Related articles === | ||
* [[2-2d. Event Trigger - Event Handler (practice)]] | * [[2-2d. Event Trigger - Event Handler (practice)]] | ||
+ | |||
+ | [[Category: AlphaCom practice]] |
Latest revision as of 10:07, 30 June 2022
Contents
Solution
Call setup:
- The Entrance and the SOS Point should be configured to make a Call Request (623 + 101) to the Control Room.
- The Control Room should be configured as a CRM (Control Room Master), the DAK display should be enabled, and the Navigation Keys should be used for call queue navigations.
Set Call Request Forwarding:
- When dialing the event trigger number 9533, or when pressing a DAK key programmed to 9533 on the Control Room station, the following features should be activated:
- Turn on Call Request Forwarding from Control Room station 101 to station 103 (M. Larsen), so that all new call requests will be forwarded to station 103. Use the command "$SCRT" for this.
- Turn on a lamp (use RCO 3) to signal that call forwarding is active
- Write to the System LOG that the call forwarding has been activated. Use the LOG "..." statement.
Reset Call Request Forwarding:
- When dialing the event trigger number 9534, or when pressing a DAK key programmed to 9534 on the Control Room station, the following features should be activated:
- Turn off Call Request Forwarding for Control Room station 101. Use the command "$SCRT" for this.
- Turn off the lamp (RCO 3) to signal that call forwarding is no longer active
- Write to the System LOG that the call forwarding has been turned off. Use the LOG "..." statement.
Program DAK 1 and DAK 2 of the Control Room station with the codes for Call Forwarding on (9533) and Call Forwarding off (9534), and add an appropriate display text.
Verify that:
- Call Forwarding is turned on and off
- RCO 3 is turned on and off
- The Call forwarding on/off is logged in the "System Log" (AlphaWeb: System Monitoring -> Logging. It might be that logging has to be enabled first: System Configuration -> Logging).