+ | Station cannot register to the server/controller | ||
− | + | Possible reasons: | |
− | + | * Invalid network settings (IP address and network mask) in the device | |
− | + | * Wrong or missing account settings (Server IP, directory number, password..) | |
− | + | * Failing to register due to missing license in the server | |
− | + | * The server is offline | |
− | * | + | * Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP) |
− | + | If the server is on a different subnet, check that | |
− | + | * A valid Default gateway is defined | |
− | |||
=Status LEDs on PCB= | =Status LEDs on PCB= | ||
Line 33: | Line 25: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
'''Flashing 2 red + 1 green''' | '''Flashing 2 red + 1 green''' | ||
− | * Station has no connection to the AlphaCom server. | + | * Station has no connection to the ICX-AlphaCom server. |
'''Flashing 1 red + 2 green''' | '''Flashing 1 red + 2 green''' | ||
− | * Station connected but NOT registered in the AlphaCom server. | + | * Station connected but NOT registered in the ICX-AlphaCom server. |
'''Flashing 3 green''' | '''Flashing 3 green''' | ||
− | * Station connected and registered in the AlphaCom server. | + | * Station connected and registered in the ICX-AlphaCom server. |
=Ethernet Activity & Speed LEDs on PCB= | =Ethernet Activity & Speed LEDs on PCB= | ||
Line 53: | Line 45: | ||
* No light: 10 Mbit Ethernet connection | * No light: 10 Mbit Ethernet connection | ||
− | [[Category: | + | [[Category: Station Indication LEDs]] |
Latest revision as of 12:48, 20 November 2020
LEDs on Front Plate
Status LEDs
- - Talk icon LED lights amber when a call is active and in conversation
- - Door icon LED lights green when the door is unlocked or relay is active
Call button LED: Flashing at 1 second intervals
Station cannot register to the server/controller
Possible reasons:
- Invalid network settings (IP address and network mask) in the device
- Wrong or missing account settings (Server IP, directory number, password..)
- Failing to register due to missing license in the server
- The server is offline
- Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
If the server is on a different subnet, check that
- A valid Default gateway is defined
Status LEDs on PCB
Flashing 2 red + 1 green
- Station has no connection to the ICX-AlphaCom server.
Flashing 1 red + 2 green
- Station connected but NOT registered in the ICX-AlphaCom server.
Flashing 3 green
- Station connected and registered in the ICX-AlphaCom server.
Ethernet Activity & Speed LEDs on PCB
Green LED
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection