Line 5: | Line 5: | ||
There are two RJ-45 ports located on the Turbine Extended Kit that are used for PoE/LAN Ethernet connection. | There are two RJ-45 ports located on the Turbine Extended Kit that are used for PoE/LAN Ethernet connection. | ||
− | There are 6 I/O | + | There are 6 I/O connectors available on the Turbine Extended Kit. These connections are used as digital input (eg. from a closing contact) or LED driver output (12mA max). |
{|border="1" | {|border="1" | ||
Line 12: | Line 12: | ||
|Secondary Power || If PoE is not available, the Turbine Extended Kit can be powered from a 24-48 VDC local power supply.** | |Secondary Power || If PoE is not available, the Turbine Extended Kit can be powered from a 24-48 VDC local power supply.** | ||
|- | |- | ||
− | |Relays || | + | |Relays || Two Double Throw relay contacts with 60W switching power. COM, NO, NC contacts are provided. |
|- | |- | ||
− | |Input/Output || 6 I/Os are available. Each I/O can be configured as either input | + | |Input/Output || 6 I/Os are available. Each I/O can be configured as either input or a 12mA LED driver output. |
|- | |- | ||
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal | |Audio Line Out || A balanced 600 ohm audio line out with induction loop signal | ||
|} | |} | ||
− | + | {{Note | Use cables crimped with ferrules for terminal block connectors}} | |
* When the Turbine Kit is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned. | * When the Turbine Kit is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned. | ||
Line 30: | Line 30: | ||
===Power Supply=== | ===Power Supply=== | ||
− | The Turbine | + | The Turbine Extended Kit supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. If PoE is not available, the Turbine Extended Kit can be connected to a 24 VDC local power supply. |
===Network Connection=== | ===Network Connection=== | ||
[[File:TKIE Connections 1.PNG|thumb|left|250px|Turbine Extended Kit]] | [[File:TKIE Connections 1.PNG|thumb|left|250px|Turbine Extended Kit]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | There | + | There are two RJ-45 ports located on the Turbine Extended Kit that is used for PoE/LAN Ethernet connection. |
=Optional Speaker/Microphone connector= | =Optional Speaker/Microphone connector= | ||
Line 41: | Line 41: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | + | ||
− | |||
− | |||
See also [[Turbine Extended Board Connectors]] | See also [[Turbine Extended Board Connectors]] | ||
+ | |||
+ | [[Category:Turbine Connections]] |
Latest revision as of 09:58, 9 June 2023
This article describes all Turbine Extended Kit connections.
There are two RJ-45 ports located on the Turbine Extended Kit that are used for PoE/LAN Ethernet connection.
There are 6 I/O connectors available on the Turbine Extended Kit. These connections are used as digital input (eg. from a closing contact) or LED driver output (12mA max).
Ethernet/Power | The Turbine Extended Kit supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.* |
Secondary Power | If PoE is not available, the Turbine Extended Kit can be powered from a 24-48 VDC local power supply.** |
Relays | Two Double Throw relay contacts with 60W switching power. COM, NO, NC contacts are provided. |
Input/Output | 6 I/Os are available. Each I/O can be configured as either input or a 12mA LED driver output. |
Audio Line Out | A balanced 600 ohm audio line out with induction loop signal |
- When the Turbine Kit is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
- To make the kit speak its IP address:
- - connect a speaker to the speaker output
- - connect a button to input 1
- - press the button after startup
Power Supply
The Turbine Extended Kit supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. If PoE is not available, the Turbine Extended Kit can be connected to a 24 VDC local power supply.
Network Connection
There are two RJ-45 ports located on the Turbine Extended Kit that is used for PoE/LAN Ethernet connection.
Optional Speaker/Microphone connector
See also Turbine Extended Board Connectors