Actions

Difference between revisions of "INCA Hotline station Restore Factory Defaults"

From Zenitel Wiki

(Created page with "It may be desired to reset an IP Hotline Station to its original settings if, for instance, the password for the web server is forgotten. The defaults can be either be set to...")
 
m (1 revision imported)
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
It may be desired to reset an IP Hotline Station to its original settings if, for instance, the password for the web server is forgotten.
+
{{APS}}
 +
This procedure is applicable for the [[IP Hotline Station - 1008070000|IP Hotline Station]].
  
The defaults can be either be set to Static IP or Activated DHCP (when there are many new IP Substations in an installation).
+
'''Procedure:'''<br>
 
+
This procedure will load factory defalt settings in the station. The unit can be set to use either '''Static IP''' or '''DHCP'''.  
=== Restore with Static IP ===
+
# '''Lift the handset''', and power up the station.
# While lifting the handset, power up the substation.
+
# Replace the handset '''after exactly 2 flashes''' of the station LED.
# When the station LED starts blinking, replace the handset '''after exactly 2 blinks'''.
+
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then lift the handset again.
# Let the LED blink for '''exactly 2 more times''', then lift the handset again.
+
# Keep the handset lifted until the LED '''flashes fast 2 time'''s (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
# Keep the handset lifted until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
 
 
# Replace the handset and the station will restart with the factory default settings.
 
# Replace the handset and the station will restart with the factory default settings.
 
[[File:IP Hotline Station LED 2.PNG|left|thumb|300px]]
 
[[File:IP Hotline Station LED 2.PNG|left|thumb|300px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
'''Factory default values:'''
 +
*Station Mode: '''Pulse'''
 +
*Station IP address: '''169.254.1.100''' (Static) or '''DHCP'''
 +
*Username: '''admin'''
 +
*Password: '''alphaadmin'''
  
{| class="wikitable"
 
!style="background:#ffdead" colspan="2"|Factory default values
 
|-
 
| Station Mode || align=center | '''Pulse'''
 
|-
 
| Station IP address || align=center | '''169.254.1.100'''
 
|-
 
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
 
* Software 01.06 and earlier: '''ADMIN/alphacom''')
 
 
=== Restore with Activated DHCP ===
 
The DHCP option is available from software version 01.07.
 
# While lifting the handset, power up the substation.
 
# When the station LED starts blinking, replace the handset '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 4 more times''', then lift the handset again.
 
# Keep the handset lifted until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 
# Replace the handset and the station will restart with the factory default settings.
 
 
{| class="wikitable"
 
!style="background:#ffdead" colspan="2"|Factory default values
 
|-
 
| Station Mode || align=center | '''Pulse'''
 
|-
 
| Station IP address || align=center | '''determined by DHCP server'''
 
|-
 
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
 
* Software 01.06 and earlier: '''ADMIN/alphacom''')
 
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 14:10, 5 February 2018

APS.png

This procedure is applicable for the IP Hotline Station.

Procedure:
This procedure will load factory defalt settings in the station. The unit can be set to use either Static IP or DHCP.

  1. Lift the handset, and power up the station.
  2. Replace the handset after exactly 2 flashes of the station LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then lift the handset again.
  4. Keep the handset lifted until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Replace the handset and the station will restart with the factory default settings.
IP Hotline Station LED 2.PNG


Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin