Difference between revisions of "INCA Masterstation PCB LED Indicators"
From Zenitel Wiki
(Created page with "== Status LED == LED3 – Bicolor SMD LED on board component side. left|thumb|400px|Status LED <br style="clear:both;" /> '''Blinkin...") |
|||
(2 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
[[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]] | [[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | '''Blinking 2 red + 1 green:''' | + | *'''Blinking 2 red + 1 green:''': Station has no connection to the ICX-AlphaCom Server. |
− | + | *'''Blinking 1 red + 2 green:''': Station connected but NOT registered in the ICX-AlphaCom Server. | |
− | + | *'''Blinking 3 green:''': Station connected and registered in the ICX-AlphaCom Server. | |
− | '''Blinking 1 red + 2 green:''' | ||
− | |||
− | |||
− | '''Blinking 3 green:''' | ||
− | |||
== Power LED == | == Power LED == | ||
Line 37: | Line 32: | ||
* No light: 10 Mbit Ethernet connection | * No light: 10 Mbit Ethernet connection | ||
− | [[Category: | + | [[Category:Station Indication LEDs]] |
Latest revision as of 08:17, 20 November 2020
Status LED
LED3 – Bicolor SMD LED on board component side.
- Blinking 2 red + 1 green:: Station has no connection to the ICX-AlphaCom Server.
- Blinking 1 red + 2 green:: Station connected but NOT registered in the ICX-AlphaCom Server.
- Blinking 3 green:: Station connected and registered in the ICX-AlphaCom Server.
Power LED
LED6 – Yellow SMD LED on board component side.
- Light: 13VDC board power OK.
- No light: 13VDC board power faulty if no other LEDs are lit.
Possible reasons:
- 24 VDC or PoE not connected
- Faulty board
LAN LEDs
Left LED:
- Steady light: Ethernet connection OK
- Blinking: Ethernet traffic
- No light: No Ethernet connection
Right LED:
- Light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection