Actions

Difference between revisions of "INCA Masterstation PCB LED Indicators"

From Zenitel Wiki

(Created page with "== Status LED == LED3 – Bicolor SMD LED on board component side. left|thumb|400px|Status LED <br style="clear:both;" /> '''Blinkin...")
 
 
(2 intermediate revisions by 2 users not shown)
Line 3: Line 3:
 
[[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]]
 
[[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
'''Blinking 2 red + 1 green:'''<br>
+
*'''Blinking 2 red + 1 green:''': Station has no connection to the ICX-AlphaCom Server.
* Station has no connection to the AlphaCom XE Audio Server.
+
*'''Blinking 1 red + 2 green:''': Station connected but NOT registered in the ICX-AlphaCom Server.
 
+
*'''Blinking 3 green:''': Station connected and registered in the ICX-AlphaCom Server.
'''Blinking 1 red + 2 green:'''<br>
 
* Station connected but NOT registered in the AlphaCom XE Audio Server.
 
 
 
'''Blinking 3 green:'''
 
* Station connected and registered in the AlphaCom XE Audio Server.
 
  
 
== Power LED ==
 
== Power LED ==
Line 37: Line 32:
 
* No light:  10 Mbit Ethernet connection
 
* No light:  10 Mbit Ethernet connection
  
[[Category:INCA Indication LEDs]]
+
[[Category:Station Indication LEDs]]

Latest revision as of 08:17, 20 November 2020

Status LED

LED3 – Bicolor SMD LED on board component side.

Status LED


  • Blinking 2 red + 1 green:: Station has no connection to the ICX-AlphaCom Server.
  • Blinking 1 red + 2 green:: Station connected but NOT registered in the ICX-AlphaCom Server.
  • Blinking 3 green:: Station connected and registered in the ICX-AlphaCom Server.

Power LED

LED6 – Yellow SMD LED on board component side.

Power LED


  • Light: 13VDC board power OK.
  • No light: 13VDC board power faulty if no other LEDs are lit.

Possible reasons:

  • 24 VDC or PoE not connected
  • Faulty board

LAN LEDs

Left LED:

Left LED


  • Steady light: Ethernet connection OK
  • Blinking: Ethernet traffic
  • No light: No Ethernet connection

Right LED:

Right LED


  • Light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection