* Relay switching capacity: Max. 9 watt (Max voltage: 60VAC/60VDC. Max current: 160mA) | * Relay switching capacity: Max. 9 watt (Max voltage: 60VAC/60VDC. Max current: 160mA) | ||
* The 5V output can deliver | * The 5V output can deliver 200 mA current maximum}} | ||
<br clear=all/> | <br clear=all/> | ||
[[Category: Turbine Connections]] | [[Category: Turbine Connections]] | ||
Latest revision as of 12:17, 22 January 2026
| Pin | Description | Comment |
| 1 | GPIO | General Purpose In Out |
| 2 | 5V+ | 5 volt output |
| 3 | Ext speaker (8ohm) | Connection for external 8 ohm loudspeaker |
| 4 | Ext speaker (8ohm) | Connection for external 8 ohm loudspeaker |
| 5 | Int speaker (8ohm) | Connection for internal 8 ohm loudspeaker |
| 6 | Int speaker (8ohm) | Connection for internal 8 ohm loudspeaker |
| 7 | Relay CO | Relay output, Common |
| 8 | Relay NO | Relay output, Normal Open |
| 9 | Line in/Mic | Audio input (positive) |
| 10 | Line in/Mic | Audio input (negative) |
| 11 | GND | Ground connector |
|
Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm². |
|