== Syntax ==
 
== Syntax ==
  
  MST  <[(node)]>  <destination>  <source>  <“mail-text”/mail-id> <[pri]>
+
  MST  <[(node)]>  <destination phys. no>  <source phys. no>  <“mail-text”/mail-id> <[priority]>
  
== Example ==
+
*Node: 1-254 (optional)
 +
*Destination phys. no: 1-552
 +
*Source phys. no: 1-552, or 0 if no source
 +
*Mail text: Free text  (maximum 16 characters) in quotes, or [[Predefined AlphaCom mails]] id: 19-30
 +
*Priority: 1-255 (optional)
  
  MST 47 0 “Temp. alarm” – Send mail-message to station 47
+
== Examples ==
  MST (3) 47 0 “Temp. alarm” 160 – Send mail w. priority 160 to station 47 in node 3
+
 
 +
  MST 47 0 "Temp. alarm"          – Send textmessage "Temp.alarm" to station 47
 +
  MST (3) 47 0 "Temp. alarm" 160   – Send "Temp.alarm" with priority 160 to station 47 in node 3
 +
MST 1 0 28                      - Send line error (28) to station 1
  
  
 
[[Category:Event Handler]]
 
[[Category:Event Handler]]
 +
[[Category:Built-In Action Commands]]

Latest revision as of 15:15, 4 October 2019

AI.png


Syntax

MST  <[(node)]>  <destination phys. no>  <source phys. no>  <“mail-text”/mail-id> <[priority]>
  • Node: 1-254 (optional)
  • Destination phys. no: 1-552
  • Source phys. no: 1-552, or 0 if no source
  • Mail text: Free text (maximum 16 characters) in quotes, or Predefined AlphaCom mails id: 19-30
  • Priority: 1-255 (optional)

Examples

MST 47 0 "Temp. alarm"           – Send textmessage "Temp.alarm" to station 47
MST (3) 47 0 "Temp. alarm" 160   – Send "Temp.alarm" with priority 160 to station 47 in node 3
MST 1 0 28                       - Send line error (28) to station 1