Actions

Difference between revisions of "IP Substation Indication LEDs"

From Zenitel Wiki

(New page: Indication LEDs STATION LED (on board and in front plate) Blinking 1 sec. interval Station does not have connection to the AlphaCom E exchange. Possible reasons: - No connection to Ether...)
 
 
(10 intermediate revisions by one other user not shown)
Line 1: Line 1:
Indication LEDs
+
#REDIRECT [[Weather and Vandal Resistant IP Substation - 1008041100]]
STATION LED (on board and in front plate)
 
Blinking 1 sec. interval Station does not have connection to the AlphaCom E exchange.
 
Possible reasons:
 
- No connection to Ethernet
 
- Wrong AlphaCom E IP address configured
 
- Invalid IP address
 
- No or wrong gateway to the AlphaCom E exchange
 
Blinking 5 sec. interval Station has connection to the AlphaCom E exchange, but has not
 
been registered.
 
Reason:
 
- Station has not been programmed in AlphaPro
 
No blinking
 
Possible reasons:
 
- Station connected and registered to the AlphaCom E exchange - All OK
 
- Station not powered up (if no other LEDs are active)
 
STATUS LED
 
Blinking 2 red + 1 green Station does not have connection to the AlphaCom E exchange
 
Blinking 1 red + 2 green Station has connection to AlphaCom E exchange, but has not been
 
registered
 
Blinking 3 green Station connected and registered in the AlphaCom E exchange
 
LAN LEDs (on LAN and AUX RJ45-jacks):
 
Left green LED:
 
- Steady light Ethernet connection OK
 
- Blinking Ethernet traffic
 
- No light No Ethernet connection
 
Right amber LED:
 
- Light 100 Mbit Ethernet connection
 
- No light 10 Mbit Ethernet connection
 

Latest revision as of 14:31, 10 February 2009