Difference between revisions of "TCIS Indication LEDs"
From Zenitel Wiki
(→Status LEDs on PCB) |
(→LEDs on Front Plate) |
||
Line 1: | Line 1: | ||
=LEDs on Front Plate= | =LEDs on Front Plate= | ||
− | |||
'''<u>Status LEDs</u>''' | '''<u>Status LEDs</u>''' | ||
:- '''Bell icon''' lights '''yellow''' when a call is placed and ringing | :- '''Bell icon''' lights '''yellow''' when a call is placed and ringing | ||
:- '''Talk icon''' lights '''green''' when a call is active and in conversation | :- '''Talk icon''' lights '''green''' when a call is active and in conversation | ||
:- '''Door icon''' lights '''red''' when the door is unlocked or relay is active | :- '''Door icon''' lights '''red''' when the door is unlocked or relay is active | ||
+ | [[File:TCIS Indications 1.PNG|thumb|700px|left]] | ||
+ | <br style="clear:both;" /> | ||
+ | |||
− | |||
− | |||
'''<u>Talk Icon: Flashing at 1 second intervals</u>''' | '''<u>Talk Icon: Flashing at 1 second intervals</u>''' | ||
:- Station has no connection to the AlphaCom server/exchange. | :- Station has no connection to the AlphaCom server/exchange. | ||
Line 16: | Line 16: | ||
::- Invalid IP address | ::- Invalid IP address | ||
::- No gateway or wrong gateway to the AlphaCom server/exchange | ::- No gateway or wrong gateway to the AlphaCom server/exchange | ||
+ | [[File:TCIS Indications 2.PNG|thumb|3200px|left]] | ||
+ | <br style="clear:both;" /> | ||
− | |||
− | |||
'''<u>Talk Icon: Flashing at 5 second intervals</u>''' | '''<u>Talk Icon: Flashing at 5 second intervals</u>''' | ||
:- Station connected but NOT registered in the AlphaCom server/exchange. | :- Station connected but NOT registered in the AlphaCom server/exchange. | ||
::'''Reason''': | ::'''Reason''': | ||
::- Station has not been programmed in AlphaPro | ::- Station has not been programmed in AlphaPro | ||
− | + | [[File:TCIS Indications 3.PNG|thumb|500px|left]] | |
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
Revision as of 09:50, 11 October 2016
LEDs on Front Plate
Status LEDs
- - Bell icon lights yellow when a call is placed and ringing
- - Talk icon lights green when a call is active and in conversation
- - Door icon lights red when the door is unlocked or relay is active
Talk Icon: Flashing at 1 second intervals
- - Station has no connection to the AlphaCom server/exchange.
- Possible reasons:
- - No connection to Ethernet
- - Wrong AlphaCom XE IP address configured
- - Invalid IP address
- - No gateway or wrong gateway to the AlphaCom server/exchange
Talk Icon: Flashing at 5 second intervals
- - Station connected but NOT registered in the AlphaCom server/exchange.
- Reason:
- - Station has not been programmed in AlphaPro
Status LEDs on PCB
Flashing 2 red + 1 green
- - Station has no connection to the AlphaCom server/exchange.
Flashing 1 red + 2 green
- - Station connected but NOT registered in the AlphaCom server/exchange.
Flashing 3 green
- - Station connected and registered in the AlphaCom server/exchange.
Ethernet Activity & Speed LEDs on PCB
Green LED
- - Steady light: Ethernet connection OK
- - Flashing: Ethernet data traffic
- - No light: No Ethernet connection
Yellow LED
- - Steady light: 100 Mbit Ethernet connection
- - No light: 10 Mbit Ethernet connection