Difference between revisions of "TCIS Indication LEDs"
From Zenitel Wiki
(→Status LEDs on PCB) |
(→Ethernet Activity & Speed LEDs on PCB) |
||
Line 45: | Line 45: | ||
[[File:TCIS Board Indications 2.png|thumb|300px|left]] | [[File:TCIS Board Indications 2.png|thumb|300px|left]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | ''' | + | '''Green LED''' |
− | + | * Steady light: Ethernet connection OK | |
− | + | * Flashing: Ethernet data traffic | |
− | + | * No light: No Ethernet connection | |
− | |||
− | |||
− | |||
− | |||
− | |||
+ | '''Yellow LED''' | ||
+ | * Steady light: 100 Mbit Ethernet connection | ||
+ | * No light: 10 Mbit Ethernet connection | ||
[[Category:Turbine]] | [[Category:Turbine]] |
Revision as of 13:43, 12 October 2016
LEDs on Front Plate
Status LEDs
- - Bell icon lights yellow when a call is placed and ringing
- - Talk icon lights green when a call is active and in conversation
- - Door icon lights red when the door is unlocked or relay is active
Talk Icon: Flashing at 1 second intervals Station has no connection to the AlphaCom server/exchange.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom XE IP address configured
- Invalid IP address
- No gateway or wrong gateway to the AlphaCom server/exchange
Talk Icon: Flashing at 5 second intervals
Station connected but NOT registered in the AlphaCom server/exchange.
Reason:
- Station has not been programmed in AlphaPro
Status LEDs on PCB
Flashing 2 red + 1 green
- Station has no connection to the AlphaCom server.
Flashing 1 red + 2 green
- Station connected but NOT registered in the AlphaCom server.
Flashing 3 green
- Station connected and registered in the AlphaCom server.
Ethernet Activity & Speed LEDs on PCB
Green LED
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection