Monitoring: MultiModule: Difference between revisions
From Zenitel Wiki
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
(Available from AMC 09.05) | |||
Send message to log and to station 1 reporting communication status with slave 1, 2 and/or 3: | Send message to log and to station 1 reporting communication status with slave 1, 2 and/or 3: | ||
[[File:Monitoring Multimodule 1.PNG|left|thumb|500px|Example 1: Send Module status to the [[System log]] for slaves connected to this exchange]] | [[File:Monitoring Multimodule 1.PNG|left|thumb|500px|Example 1: Send Module status to the [[System log]] for slaves connected to this exchange]] | ||
Revision as of 14:02, 27 August 2013
(Available from AMC 09.05)
Send message to log and to station 1 reporting communication status with slave 1, 2 and/or 3:
Example 1: Send Module status to the System log for slaves connected to this exchange
IF %op(%sev,=,66) LOG "Communication %chg(UP,DOWN): Slave 1" MST 1 0 "Slave 1 %chg(UP,DOWN)" STOP ENDIF IF %op(%sev,=,67) LOG "Communication %chg(UP,DOWN): Slave 2" MST 1 0 "Slave 2 %chg(UP,DOWN)" STOP ENDIF IF %op(%sev,=,68) LOG "Communication %chg(UP,DOWN): Slave 3" MST 1 0 "Slave 3 %chg(UP,DOWN)" STOP ENDIF