Revision as of 12:46, 13 October 2016
LEDs on Front Plate
Power LED - Green:
- Steady light: Power is OK
Fault LED - Yellow:
- Steady light: Not used
- Flashing: Not registered/no connection to server
Call LED - Red:
- Steady light: In a conversation/call
Status LEDs on PCB
Flashing 2 red + 1 green:
- Station has no connection to the AlphaCom server/exchange.
Flashing 1 red + 2 green:
- Station connected but NOT registered in the AlphaCom server/exchange.
Flashing 3 green
- Station connected and registered in the AlphaCom server/exchange.
Ethernet Activity & Speed LEDs on PCB
Green LED
- - Steady light: Ethernet connection OK
- - Flashing: Ethernet data traffic
- - No light: No Ethernet connection
Yellow LED
- - Steady light: 100 Mbit Ethernet connection
- - No light: 10 Mbit Ethernet connection