(Created page with "This is an article explaining in detail how to configure Door Opening. Door Opening is a standard feature in the AlphaCom. The way it works is that when an operator is in a ...")
 
(Event Handler)
Line 13: Line 13:
  
 
In the '''Event Actions''' window click the ''Insert'' button and create an event like this:
 
In the '''Event Actions''' window click the ''Insert'' button and create an event like this:
 +
[[File:EventHandler Event2.PNG|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 +
This event is triggered when the operator dials digit 6 while in covnersation with the door. Physical number 6 (the door station) is the owner of the event. This is where it happens. '''When Related To''' can be set to all, meaning whoever in conversation with the door is allowed to dial digit 6 to open the door. In this example we have chosen to limit this acces by selecting a single station; Directory number 120.
 +
 +
At the end of the event RCO 6 is chosen as the triggered action caused by the event.

Revision as of 08:06, 22 May 2015

This is an article explaining in detail how to configure Door Opening.

Door Opening is a standard feature in the AlphaCom. The way it works is that when an operator is in a conversation with a door station, the operator kan dial digit 6 to activate an RCO. The RCO will in turn activate a relay which again releases the door lock. But, for all this to happen we need to assist the server with some details.

Event Handler

We need to define who this event is for, and which output to activate. This is done using the Event Handler. Go to Exhcange&System from the top menu in AlphaPro:

AlphaPro Exchange and System icon.png


From the Exchange&System window choose the Events button:

Exchange System Events.png


In the Event Actions window click the Insert button and create an event like this:

EventHandler Event2.PNG


This event is triggered when the operator dials digit 6 while in covnersation with the door. Physical number 6 (the door station) is the owner of the event. This is where it happens. When Related To can be set to all, meaning whoever in conversation with the door is allowed to dial digit 6 to open the door. In this example we have chosen to limit this acces by selecting a single station; Directory number 120.