Difference between revisions of "Flowire clusters"
From Zenitel Wiki
Line 4: | Line 4: | ||
Cluster separation can be achieved in two ways: | Cluster separation can be achieved in two ways: | ||
+ | * '''Separation by NMK Password''' | ||
* '''Physical separation''' | * '''Physical separation''' | ||
− | |||
− | |||
− | |||
− | |||
== Separation by NMK Password == | == Separation by NMK Password == | ||
− | + | The recommended way is to separate clusters by using different NMK Passwords. When implementing different NMK Passwords, it will not be possible for a flowire unit to "jump" to another cluster with a different password. | |
− | |||
In your case, if these 3 Flowires on the picture are on three different clusters, password separation is necessary, else you will have trouble for sure. | In your case, if these 3 Flowires on the picture are on three different clusters, password separation is necessary, else you will have trouble for sure. | ||
Line 19: | Line 15: | ||
All Flowires within the same cluster must have same PW, else they cannot communicate. | All Flowires within the same cluster must have same PW, else they cannot communicate. | ||
− | HomePlugAV0123 | + | Default NMK Password: '''HomePlugAV0123''' |
+ | |||
+ | |||
+ | == Physical separation == | ||
+ | Both the Flowire units, the power cable, and the link cable must have have a certain distance between them. Minimum distance is 5 cm. Crosstalk might appear if for instance the cables for two different clusters are running on each side of a wall. |
Revision as of 09:30, 26 August 2015
When there are several Flowire clusters in an installation, the different clusters must be separated to avoid crosstalk between the clusters. When crosstalk is present, a Flowire unit on one cluster might "jump over" to the other cluster, causing errors in the communication.
Cluster separation can be achieved in two ways:
- Separation by NMK Password
- Physical separation
Separation by NMK Password
The recommended way is to separate clusters by using different NMK Passwords. When implementing different NMK Passwords, it will not be possible for a flowire unit to "jump" to another cluster with a different password.
In your case, if these 3 Flowires on the picture are on three different clusters, password separation is necessary, else you will have trouble for sure.
All Flowires within the same cluster must have same PW, else they cannot communicate.
Default NMK Password: HomePlugAV0123
Physical separation
Both the Flowire units, the power cable, and the link cable must have have a certain distance between them. Minimum distance is 5 cm. Crosstalk might appear if for instance the cables for two different clusters are running on each side of a wall.