Actions

Difference between revisions of "IP Flush Master Gooseneck"

From Zenitel Wiki

Line 1: Line 1:
 
[[File:80975_RS.jpg|thumb|Gooseneck Microphone]]
 
[[File:80975_RS.jpg|thumb|Gooseneck Microphone]]
:* Item number: [[Gooseneck Microphone - 1008097500|1008097500]]
+
:* Item number: 1008097500
 
This item applies to the IP Flush Master Station and the IP Master Station Kit.
 
This item applies to the IP Flush Master Station and the IP Master Station Kit.
  

Revision as of 12:25, 24 October 2016

Gooseneck Microphone
  • Item number: 1008097500

This item applies to the IP Flush Master Station and the IP Master Station Kit.

To install the Gooseneck Microphone:

  • Remove the cover plug from the opening for the microphone on the front panel.
  • Thread the microphone cable through the opening, the lock washer and nut.
  • Tighten the nut on the microphone’s threaded stud.
  • Insert the microphone’s IDC socket into the upper two pins of the 3-pin header (J7) located at the lower left side of the station. The signal wire (white) should be on the top pin while the ground wire (green) should be on the bottom pin.
  • Slide the S1 switch (bottom back of station) to EXT to activate the external microphone function.

See Related Article INCA Master Station Kit Board Connectors.

IP Master Gooseneck Microphone Installation.PNG
Installing the Gooseneck Microphone


Gooseneck microphone connection
Gooseneck microphone connection, detailed


Additional Documentation on Zenitel.com