Station LED
LED4 - Red 5mm LED on board rear side.
This LED is on some models visible through the front plate, on others not.
Blinking at 1 second intervals:
Station has no connection to the AlphaCom XE Audio Server.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom IP address configured
- Invalid IP address
- No gateway or wrong gateway to the AlphaCom XE Audio Server
Blinking at 5 second intervals:
Station connected but NOT registered in the AlphaCom XE Audio Server.
Possible reasons:
- Station has not been programmed in AlphaPro
- Missing IP Station license in AlphaCom XE Audio Server
No blinking:
Possible reasons:
- Station connected and registered to the AlphaCom XE Audio Server
- Station not powered up (if no other LEDs are active)