INCA Masterstation PCB LED Indicators: Difference between revisions
From Zenitel Wiki
(Created page with "== Status LED == LED3 – Bicolor SMD LED on board component side. left|thumb|400px|Status LED <br style="clear:both;" /> '''Blinkin...") |
|||
| Line 3: | Line 3: | ||
[[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]] | [[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
'''Blinking 2 red + 1 green:''' | *'''Blinking 2 red + 1 green:''': Station has no connection to the AlphaCom XE Audio Server. | ||
*'''Blinking 1 red + 2 green:''': Station connected but NOT registered in the AlphaCom XE Audio Server. | |||
*'''Blinking 3 green:''': Station connected and registered in the AlphaCom XE Audio Server. | |||
'''Blinking 1 red + 2 green:''' | |||
'''Blinking 3 green:''' | |||
== Power LED == | == Power LED == | ||
Revision as of 11:00, 26 October 2016
Status LED
LED3 – Bicolor SMD LED on board component side.
- Blinking 2 red + 1 green:: Station has no connection to the AlphaCom XE Audio Server.
- Blinking 1 red + 2 green:: Station connected but NOT registered in the AlphaCom XE Audio Server.
- Blinking 3 green:: Station connected and registered in the AlphaCom XE Audio Server.
Power LED
LED6 – Yellow SMD LED on board component side.
- Light: 13VDC board power OK.
- No light: 13VDC board power faulty if no other LEDs are lit.
Possible reasons:
- 24 VDC or PoE not connected
- Faulty board
LAN LEDs
Left LED:
- Steady light: Ethernet connection OK
- Blinking: Ethernet traffic
- No light: No Ethernet connection
Right LED:
- Light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection