Difference between revisions of "IP-ARIO Restore Factory Defaults"
From Zenitel Wiki
(Created page with "==Factory Default IP Settings== To configure the IP-ARIO unit with Factory Default IP Settings do the following: # Disconnect power to the unit. <br/> # Reconnect power and wi...") |
(→Factory Default IP Settings) |
||
Line 8: | Line 8: | ||
[[File:IP-ARIOConfig10.PNG|thumb|left|500px|Front view]] | [[File:IP-ARIOConfig10.PNG|thumb|left|500px|Front view]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
+ | |||
+ | {| class="wikitable" | ||
+ | !style="background:#ffdead" colspan="2"|Factory default values | ||
+ | |- | ||
+ | | Station Mode || align=center | '''AlphaCom''' | ||
+ | |- | ||
+ | | Station IP address || align=center | '''169.254.1.100''' | ||
+ | |- | ||
+ | | AlphaCom IP address || align=center | '''169.254.1.5''' | ||
+ | |- | ||
+ | | Username* || align=center | '''admin''' | ||
+ | |- | ||
+ | | Password* || align=center | '''alphaadmin''' | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | * Software 01.06 and earlier: '''ADMIN/alphacom''') |
Revision as of 11:12, 26 October 2016
Factory Default IP Settings
To configure the IP-ARIO unit with Factory Default IP Settings do the following:
- Disconnect power to the unit.
- Reconnect power and within 5 seconds, use a pin to press and hold the pinhole Reset button (on the front right of the unit).
- Keep the Reset button pressed until the CALL LED emits 3 slow flashes followed by 3 fast flashes as confirmation that the unit is reset. (Takes appr. 25 seconds)
- Release the Reset button.
The unit’s IP settings will now be reset to the factory default values with IP address 169.254.1.100.
Factory default values | |
---|---|
Station Mode | AlphaCom |
Station IP address | 169.254.1.100 |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)