Difference between revisions of "IP Heavy Duty - Restore Factory Defaults"
From Zenitel Wiki
Line 1: | Line 1: | ||
− | {{APS}}This procedure is applicable for the [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]] | + | {{APS}} [[File:IP HeavyDuty.png|thumb|250px|The IP Heavy Duty Stations]] |
+ | This procedure is applicable for the [[IP Heavy Duty Station|IP Heavy Duty station 1008072xx0]] | ||
The Factory Default can be either set to '''Static''' IP 169.254.1.100 or activate '''DHCP'''. | The Factory Default can be either set to '''Static''' IP 169.254.1.100 or activate '''DHCP'''. |
Revision as of 14:10, 17 March 2017
This procedure is applicable for the IP Heavy Duty station 1008072xx0
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
Restore with Static IP
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While pressing the button, power up the station kit.
- When the station kit LED starts blinking, release the button after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Release the button and the station kit will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: From DHCP server
- Username: admin
- Password: alphaadmin