Difference between revisions of "TouchLine Key Signaling"
From Zenitel Wiki
(→Two Tone Signaling) |
|||
Line 18: | Line 18: | ||
* Digit 8: 2100 Hz | * Digit 8: 2100 Hz | ||
* Digit 9: 2300 Hz | * Digit 9: 2300 Hz | ||
− | |||
− | |||
− | |||
== Two Tone Signaling== | == Two Tone Signaling== | ||
− | In addition to the | + | In addition to the keyboard digits 0 - 9 another set of 10 tones are used for DAK signaling for CRM IV, Dual Display and PrisCom stations. |
These tones 10-19 are sinewave tones in the range 600Hz to 2400 Hz, at 200 Hz steps. | These tones 10-19 are sinewave tones in the range 600Hz to 2400 Hz, at 200 Hz steps. |
Revision as of 11:01, 10 May 2007
Signalig protocol
To types of signaling protocols used towards the stations, Current Signaling and Tone Signaling
Contents
Current Signaling
Single Tone Signaling
Station keyboard digits 0 - 9 use sinewave tones in the range 500Hz to 2300 Hz, at 200 Hz steps.
- Digit 0: 500 Hz
- Digit 1: 700 Hz
- Digit 2: 900 Hz
- Digit 3: 1100 Hz
- Digit 4: 1300 Hz
- Digit 5: 1500 Hz
- Digit 6: 1700 Hz
- Digit 7: 1900 Hz
- Digit 8: 2100 Hz
- Digit 9: 2300 Hz
Two Tone Signaling
In addition to the keyboard digits 0 - 9 another set of 10 tones are used for DAK signaling for CRM IV, Dual Display and PrisCom stations.
These tones 10-19 are sinewave tones in the range 600Hz to 2400 Hz, at 200 Hz steps.
The Two Tone signaling is used by the PrisCom Stations.
- Key board digit 0-9
- Digit Tone 0-9
- DAK D1-D15
- Digit tone 10 + 0 to 10 + 14
- DAK D16-D30
- Digit tone 11 + 0 to 11 + 14
- DAK D31-D45
- Digit tone 12 + 0 to 12 + 14
- DAK D46-D60
- Digit tone 13 + 0 to 13 + 14
- DAK D61-D75
- Digit tone 14 + 0 to 14 + 14
- DAK D76-D90
- Digit tone 15 + 0 to 15 + 14
- DAK D91-D100
- Digit tone 16 + 0 to 16 + 9
Optional DAK Acknowledge
If the station is configured with acknowledge on DAK keys:
- The AMC application will send an acknowledge message by the Display Text Protocol.
- The station will acknowled this by sending tone 18.