Actions

Difference between revisions of "Serial port pinout"

From Zenitel Wiki

Line 17: Line 17:
 
|}
 
|}
 
<br\><br\>
 
<br\><br\>
Cabling between RIO unit and AlphaCom E using multidrop RS485:
+
Cabling between [[RIO]] unit and AlphaCom E using multidrop RS485:
 
{|border="1"  
 
{|border="1"  
 
|-
 
|-

Revision as of 11:33, 17 August 2007

In the AlphaCom E20 and E26 the two serial ports are available on RJ45 connectors. In the AlphaCom E7 serial port 0 is 9 pin DSUB, and serial poret 1 is RJ45.

The serial port 0 can be RS232 only, the serial port 1 can be RS232, RS422 or RS485.

The pinout on the RJ45 connector is as follows:

RJ45 pinout
RS232 3 = TX<br\>6 = RX<br\> 4&5 = GND
RS422 1 = RX-<br\>2 = RX+<br\>7 = TX-<br\>8 = TX+
RS485 1/7 = Data - <br\> 2/8 = Data+

<br\><br\> Cabling between RIO unit and AlphaCom E using multidrop RS485:

RJ45 - AlphaCom E RIO 15 p DSUB
1 (RX-) 9 (TX+)
2 (RX+) 2 (TX-)
7 (TX+) 11 (RX+)
8 (TX+) 4 (RX-)