Cabling between [[RIO]] unit and AlphaCom E using multidrop RS485:
 
{|border="1"
 
|-
 
!style="background:#ffdead;" width="100pt"|RJ45 - AlphaCom E
 
!style="background:#ffdead;" width="100pt"|RIO 15 p DSUB
 
|-
 
|1 (RX-)||9 (TX+)
 
|-
 
|2 (RX+)||2 (TX-)
 
|-
 
|7 (TX-)||11 (RX+)
 
|-
 
|8 (TX+)||4 (RX-)
 
|-
 
|}
 
  
 
[[RIO]]: Multidrop (RS485) cabling:
 
[[RIO]]: Multidrop (RS485) cabling:

Revision as of 15:55, 28 February 2008

In the AlphaCom E20 and E26 exchanges the two serial ports are available on RJ45 connectors. In the AlphaCom E7 serial port 0 is 9 pin DSUB, and serial port 1 is on a RJ45 connector.

The serial port 0 is RS232 only, the serial port 1 can be RS232, RS422 or RS485.

The pinout on the RJ45 connector is as follows:

RJ45 pinout
RS232 3 = TX<br\>6 = RX<br\> 4&5 = GND
RS422 1 = RX-<br\>2 = RX+<br\>7 = TX-<br\>8 = TX+
RS485 1/7 = Data - <br\> 2/8 = Data+

<br\><br\>

Adaptor cable from RJ-45 to 9-pin Female D-SUB:

RJ45 - AlphaCom E 9 p Female DSUB
3 2
5 5
6 3


RIO: Multidrop (RS485) cabling:

 AlphaCom               RIO #1                  RIO #n           
 Serial 1             15 pin DSUB             15 pin DSUB
  RJ45

   1 -----------------+-- 9 --+----------------+-- 9
                      |       |                |
                      --- 11---                --- 11

   7 -----------------+-- 2 --+----------------+-- 2
                      |       |                |
                      --- 4 ---                --- 4