Difference between revisions of "TCAS Connections"
From Zenitel Wiki
(→Wiring) |
|||
Line 2: | Line 2: | ||
[[File:TCAS Connections 1.PNG|thumb|right500px|TCAS substation - Rear side]] | [[File:TCAS Connections 1.PNG|thumb|right500px|TCAS substation - Rear side]] | ||
This article describes connection details of the analog intercoms [[TCAS-1]], [[TCAS-2]] and [[TCAS-3]]. | This article describes connection details of the analog intercoms [[TCAS-1]], [[TCAS-2]] and [[TCAS-3]]. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==Wiring== | ==Wiring== |
Revision as of 12:30, 16 August 2018
This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.
Wiring
The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:
- 0.5 mm wires: 1.4 km
- 0.6 mm wires: 2.0 km
- 0.9 mm wires: 4.0 km
The station line is connected to the station by means of an RJ45 connector, or optional by using the plugable screw connector.
The station cable is not a 1:1 cable! |
For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board
Second Call Key
The station is prepared for a future second call key (DAK2).
This second call key can be found on the print if wanted and utilized with an external call button.
- A second external call key must be connected between the A-wire and the lower leg on D6 (highlighted in the image above).