Actions

Difference between revisions of "TCAS Connections"

From Zenitel Wiki

(Wiring)
Line 9: Line 9:
 
* 0.9 mm wires: 4.0 km
 
* 0.9 mm wires: 4.0 km
  
The station line is connected to the station by means of an RJ45 connector at the rear side of the station, or optional by using the plugable screw connector.
+
The station line can be connected in to ways: 
 +
* By means of an RJ45 connector at the rear side of the station, or
 +
* By using the plugable screw connector
  
 
[[File:WiringAnalogTCAS.png|thumb|left|800px]]
 
[[File:WiringAnalogTCAS.png|thumb|left|800px]]

Revision as of 11:47, 31 August 2018

AlphaCom icon 300px.png
TCAS substation - Rear side

This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.

Wiring

The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:

  • 0.5 mm wires: 1.4 km
  • 0.6 mm wires: 2.0 km
  • 0.9 mm wires: 4.0 km

The station line can be connected in to ways:

  • By means of an RJ45 connector at the rear side of the station, or
  • By using the plugable screw connector
WiringAnalogTCAS.png


Note icon The station cable is not a 1:1 cable!


For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board


Second Call Key

The station is prepared for a future second call key (DAK2).

This second call key can be found on the print if wanted and utilized with an external call button.

TCAS Connections 2.PNG


  • A second external call key must be connected between the A-wire and the lower leg on D6 (highlighted in the image above).