'''Call button LED: Flashing at 1 second intervals'''
'''Call button LED: Flashing at 1 second intervals'''
Station has no connection to the AlphaCom server/exchange.
Station has no connection to the ICX-AlphaCom server.


Possible reasons:
Possible reasons:
Line 14: Line 14:
* Wrong AlphaCom XE IP address configured  
* Wrong AlphaCom XE IP address configured  
* Invalid IP address  
* Invalid IP address  
* No gateway or wrong gateway to the AlphaCom server/exchange
* No gateway or wrong gateway to the ICX-AlphaCom server


[[File:TMIS-1 LED icon2.PNG|thumb|100px|left]]
[[File:TMIS-1 LED icon2.PNG|thumb|100px|left]]
Line 21: Line 21:


'''Call button LED: Flashing at 5 second intervals'''
'''Call button LED: Flashing at 5 second intervals'''
Station connected but NOT registered in the AlphaCom server/exchange.  
Station connected but NOT registered in the ICX-AlphaCom server.  


Reason:
Reason:
Line 33: Line 33:
<br style="clear:both;" />
<br style="clear:both;" />
'''Flashing 2 red + 1 green'''
'''Flashing 2 red + 1 green'''
* Station has no connection to the AlphaCom server.
* Station has no connection to the ICX-AlphaCom server.


'''Flashing 1 red + 2 green'''
'''Flashing 1 red + 2 green'''
* Station connected but NOT registered in the AlphaCom server.
* Station connected but NOT registered in the ICX-AlphaCom server.


'''Flashing 3 green'''
'''Flashing 3 green'''
* Station connected and registered in the AlphaCom server.
* Station connected and registered in the ICX-AlphaCom server.


=Ethernet Activity & Speed LEDs on PCB=
=Ethernet Activity & Speed LEDs on PCB=

Revision as of 08:26, 20 November 2020

LEDs on Front Plate

Status LEDs

- Talk icon LED lights amber when a call is active and in conversation
- Door icon LED lights green when the door is unlocked or relay is active
TMIS-1 LED icon1.PNG



Call button LED: Flashing at 1 second intervals Station has no connection to the ICX-AlphaCom server.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom XE IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the ICX-AlphaCom server
TMIS-1 LED icon2.PNG



Call button LED: Flashing at 5 second intervals Station connected but NOT registered in the ICX-AlphaCom server.

Reason:

  • Station has not been programmed in AlphaPro
TCIS Indications 3.PNG


Status LEDs on PCB

TCIS Board Indications 1.png


Flashing 2 red + 1 green

  • Station has no connection to the ICX-AlphaCom server.

Flashing 1 red + 2 green

  • Station connected but NOT registered in the ICX-AlphaCom server.

Flashing 3 green

  • Station connected and registered in the ICX-AlphaCom server.

Ethernet Activity & Speed LEDs on PCB

TCIS Board Indications 2.png


Green LED

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection