Difference between revisions of "TMIS Indication LEDs"
From Zenitel Wiki
(→LEDs on Front Plate) |
|||
Line 8: | Line 8: | ||
'''Call button LED: Flashing at 1 second intervals''' | '''Call button LED: Flashing at 1 second intervals''' | ||
− | Station | + | Station cannot register to the server/controller |
Possible reasons: | Possible reasons: | ||
− | * | + | * Invalid network settings (IP address and network mask) in the device |
− | * Wrong | + | * Wrong or missing account settings (Server IP, directory number, password..) |
− | * | + | * Failing to register due to missing license in the server |
− | * | + | * The server is offline |
+ | * Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP) | ||
+ | If the server is on a different subnet, check that | ||
+ | * A valid Default gateway is defined | ||
[[File:TMIS-1 LED icon2.PNG|thumb|100px|left]] | [[File:TMIS-1 LED icon2.PNG|thumb|100px|left]] |
Revision as of 12:45, 20 November 2020
LEDs on Front Plate
Status LEDs
- - Talk icon LED lights amber when a call is active and in conversation
- - Door icon LED lights green when the door is unlocked or relay is active
Call button LED: Flashing at 1 second intervals
Station cannot register to the server/controller
Possible reasons:
- Invalid network settings (IP address and network mask) in the device
- Wrong or missing account settings (Server IP, directory number, password..)
- Failing to register due to missing license in the server
- The server is offline
- Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
If the server is on a different subnet, check that
- A valid Default gateway is defined
Call button LED: Flashing at 5 second intervals
Station connected but NOT registered in the ICX-AlphaCom server.
Reason:
- Station has not been programmed in AlphaPro
Status LEDs on PCB
Flashing 2 red + 1 green
- Station has no connection to the ICX-AlphaCom server.
Flashing 1 red + 2 green
- Station connected but NOT registered in the ICX-AlphaCom server.
Flashing 3 green
- Station connected and registered in the ICX-AlphaCom server.
Ethernet Activity & Speed LEDs on PCB
Green LED
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED
- Steady light: 100 Mbit Ethernet connection