Difference between revisions of "AlphaCom supervision of protocol converter daemons"
From Zenitel Wiki
(New page: SIPD and RMD are connected to AMCD through local sockets using Stentofon Simple Link Layer *The daemons sends Idle frames every 5? second. *If no idle frame is received from the d...) |
|||
Line 1: | Line 1: | ||
− | |||
SIPD and RMD are connected to AMCD through local sockets using [[Stentofon Simple Link Layer]] | SIPD and RMD are connected to AMCD through local sockets using [[Stentofon Simple Link Layer]] | ||
− | *The daemons | + | *The daemons send an idle frames to AMCD every 5? second. |
− | *If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using: | + | *If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either: |
− | + | /opt/amc/script/rmd stop | |
or | or | ||
− | + | /opt/amc/script/sipd stop | |
*5 seconds later the deamon is restarted by AMCD using: | *5 seconds later the deamon is restarted by AMCD using: | ||
− | + | /opt/amc/script/rmd start | |
or | or | ||
− | + | /opt/amc/script/sipd start | |
* If no idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this will be done 5 times. | * If no idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this will be done 5 times. |
Revision as of 03:22, 25 May 2007
SIPD and RMD are connected to AMCD through local sockets using Stentofon Simple Link Layer
- The daemons send an idle frames to AMCD every 5? second.
- If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either:
/opt/amc/script/rmd stop
or
/opt/amc/script/sipd stop
- 5 seconds later the deamon is restarted by AMCD using:
/opt/amc/script/rmd start
or
/opt/amc/script/sipd start
- If no idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this will be done 5 times.