Actions

AlphaCom supervision of protocol converter daemons: Difference between revisions

From Zenitel Wiki

No edit summary
No edit summary
Line 1: Line 1:
SIPD and RMD are connected to AMCD through local sockets using [[Stentofon Simple Link Layer]]  
SIPD and RMD are connected to AMCD through local sockets using [[Stentofon Simple Link Layer]]  


*The daemons send an idle frames to AMCD every 5? second.
*The daemon send an idle frame to AMCD every 5? second.


*If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either:
*If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either:
Line 8: Line 7:
or
or
  /opt/amc/script/sipd stop
  /opt/amc/script/sipd stop
*5 seconds later the deamon is restarted by AMCD using:
*5 seconds later the deamon is restarted by AMCD using:
  /opt/amc/script/rmd start
  /opt/amc/script/rmd start
or
or
  /opt/amc/script/sipd start
  /opt/amc/script/sipd start
* If no idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this will be done 5 times.
* If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times.

Revision as of 02:24, 25 May 2007

SIPD and RMD are connected to AMCD through local sockets using Stentofon Simple Link Layer

  • The daemon send an idle frame to AMCD every 5? second.
  • If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either:
/opt/amc/script/rmd stop

or

/opt/amc/script/sipd stop
  • 5 seconds later the deamon is restarted by AMCD using:
/opt/amc/script/rmd start

or

/opt/amc/script/sipd start
  • If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times.
MediaWiki spam blocked by CleanTalk.