Difference between revisions of "AlphaCom supervision of protocol converter daemons"
From Zenitel Wiki
Line 1: | Line 1: | ||
− | |||
SIPD and RMD are connected to AMCD through local sockets using [[Stentofon Simple Link Layer]] | SIPD and RMD are connected to AMCD through local sockets using [[Stentofon Simple Link Layer]] | ||
− | *The | + | *The daemon send an idle frame to AMCD every 5? second. |
*If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either: | *If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either: | ||
Line 8: | Line 7: | ||
or | or | ||
/opt/amc/script/sipd stop | /opt/amc/script/sipd stop | ||
+ | |||
*5 seconds later the deamon is restarted by AMCD using: | *5 seconds later the deamon is restarted by AMCD using: | ||
/opt/amc/script/rmd start | /opt/amc/script/rmd start | ||
or | or | ||
/opt/amc/script/sipd start | /opt/amc/script/sipd start | ||
− | * If no idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this will be | + | * If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times. |
Revision as of 03:24, 25 May 2007
SIPD and RMD are connected to AMCD through local sockets using Stentofon Simple Link Layer
- The daemon send an idle frame to AMCD every 5? second.
- If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either:
/opt/amc/script/rmd stop
or
/opt/amc/script/sipd stop
- 5 seconds later the deamon is restarted by AMCD using:
/opt/amc/script/rmd start
or
/opt/amc/script/sipd start
- If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times.