Actions

Difference between revisions of "AlphaCom supervision of protocol converter daemons"

From Zenitel Wiki

Line 1: Line 1:
SIPD and RMD are connected to AMCD through local sockets using [[Stentofon Simple Link Layer]]  
+
[[SIPD]] and [[RMD]] are connected to [[AMCD]] through local sockets using [[Stentofon Simple Link Layer]]  
  
*The daemon send an idle frame to AMCD every 5? second.
+
*The daemon send an idle frame to [[AMCD]] every 5? second.
  
 
*If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either:
 
*If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either:
Line 8: Line 8:
 
  /opt/amc/script/sipd stop
 
  /opt/amc/script/sipd stop
  
*5 seconds later the deamon is restarted by AMCD using:
+
*5 seconds later the deamon is restarted by [[AMCD]] using:
 
  /opt/amc/script/rmd start
 
  /opt/amc/script/rmd start
 
or
 
or
 
  /opt/amc/script/sipd start
 
  /opt/amc/script/sipd start
 +
 
* If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times.
 
* If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times.

Revision as of 03:25, 25 May 2007

SIPD and RMD are connected to AMCD through local sockets using Stentofon Simple Link Layer

  • The daemon send an idle frame to AMCD every 5? second.
  • If no idle frame is received from the daemon within 30 second the daemon is terminated by AMCD using either:
/opt/amc/script/rmd stop

or

/opt/amc/script/sipd stop
  • 5 seconds later the deamon is restarted by AMCD using:
/opt/amc/script/rmd start

or

/opt/amc/script/sipd start
  • If no new idle frame is received from the daemon within 30 second the stop/start procedure is repeated, this sequence will be repeated 5 times.