Line 7: Line 7:
 
|style="width:100"|'''AMC 08.10'''
 
|style="width:100"|'''AMC 08.10'''
 
|-
 
|-
|colspan="5"|'''$SMT  L101  W0000  Q60'''  <BR\> '''$SMT  L%1.DIR()  W%1.TAG()  Q60''' ''example use in RECEIVED_MAIL event''
+
|colspan="2"|'''$SMT  L101  W0000  Q60'''  <BR\> '''$SMT  L%1.DIR()  W%1.TAG()  Q60'''
 +
|colspan="3" |''example use in RECEIVED_MAIL event''
 
|-
 
|-
 
|colspan="5"|Set the timer of a mail queue entry. <BR\> When timeout, the event MAIL_TIMEOUT is generated.  10 seconds later the mail queue entry will be deleted automatically.  (All new mails are initialized by the AMC to max timer.)
 
|colspan="5"|Set the timer of a mail queue entry. <BR\> When timeout, the event MAIL_TIMEOUT is generated.  10 seconds later the mail queue entry will be deleted automatically.  (All new mails are initialized by the AMC to max timer.)

Revision as of 13:57, 8 June 2007

SET_MAIL_TIMEOUT 0x0082 130 AMC 08.10
$SMT L101 W0000 Q60 <BR\> $SMT L%1.DIR() W%1.TAG() Q60 example use in RECEIVED_MAIL event
Set the timer of a mail queue entry. <BR\> When timeout, the event MAIL_TIMEOUT is generated. 10 seconds later the mail queue entry will be deleted automatically. (All new mails are initialized by the AMC to max timer.)
1 NET_OBJ_REF {ECL_STATION} Station.
2 UINT2 Mail tag (unique id) for current queue entry.
3 UINT4 Timeout value in seconds.<BR\>- The timer is ticked every 10 seconds. This means that the minimum timer value is 10 seconds, and longer times should be specified with last digit 0.<BR\>- The longest possible time is 655350 seconds, which is 7.5 days <BR\>- The system guarantees a minimum timeout as specified, worst case 10 seconds later. Ex: setting 60 seconds generates timeout 60 - 69 seconds later.
Response: COMMAND_RESPONSE