{{Code2|
{{Code2|
  IF %op(%sev,<nowiki>=</nowiki>,1)
  IF %busy(%1.phy)
If %udd(%1.phy)
LOG "Unmute microphone of %1.dir"
$DIP L%1.dir "auo 1"
IND %1.phy 2 2 1 OFF
WUDD %1.phy 0
  stop
  stop
  ENDIF
  endif
  $SM L%1.dir L%2.dir U40 NM11 GV U0
 
LOG "Mute microphone of %1.dir"
  $DIP L%1.dir "auo 8"
IND %1.phy 2 2 1 ON
WUDD %1.phy 1
endif
}}
}}



Revision as of 16:30, 14 February 2025

AI.png

In ICX-AlphaCom there is no standard feature for muting the microphone during a call, while keeping the loudspeaker active.

This article describes how you can configure a DAK key to toggle "Mic mute" on and off. If the station DAK key has a LED (e.g. CRM-V station), the green LED will be lit when muted.

In AlphaPro, select Users & Stations and select the station to have the mute function from the list. Select the button Events and Insert an event with the following properties:

Event for Mute Microphone


Action commands:

IF %busy(%1.phy)

If %udd(%1.phy)

LOG "Unmute microphone of %1.dir"
$DIP L%1.dir "auo 1"
IND %1.phy 2 2 1 OFF
WUDD %1.phy 0
stop
endif
LOG "Mute microphone of %1.dir"
$DIP L%1.dir "auo 8"
IND %1.phy 2 2 1 ON
WUDD %1.phy 1
endif