Revision as of 21:34, 17 December 2007
| WAKE_UP | 0x0047 | 71 | AMC 06.00 | |
|---|---|---|---|---|
| $WKUP L101 W1999 U12 U31 U23 U59 U59<br\>$WKUP L101 | ||||
| Register or remove wake-up request.<br\>If there is already a request, it will be replaced. | ||||
| 1 | NET_OBJ_REF<br\>{ECL_STATION} | Station. | ||
| 2 | CLOCK<br\>(optional) | Wake up time.<br\>Omitting this parameter will cause removal of any wake-up request | ||
| Response: | WAKE_UP_ACK, WAKE_UP_NAK | |||