Actions

Difference between revisions of "SET SYSTEM TIME"

From Zenitel Wiki

m (Text replacement - "<br\>" to "<br />")
Line 6: Line 6:
 
!style="background:#ffdead;" |AMC 05.00
 
!style="background:#ffdead;" |AMC 05.00
 
|-
 
|-
|colspan="5"|'''$SST W1999  U12  U31  U23  U59  U59''' <br\> '''$SST FFFF FF FF U03 U02 FF'''
+
|colspan="5"|'''$SST W1999  U12  U31  U23  U59  U59''' <br /> '''$SST FFFF FF FF U03 U02 FF'''
 
|-
 
|-
 
|colspan="5"|Set a device’s internal clock to the given date and time.  
 
|colspan="5"|Set a device’s internal clock to the given date and time.  
 
|-
 
|-
|align=center|1||[[CLOCK]]||colspan="3"|Date and time<br\>[[AMC]] 08.01:  Use the value 0xFF in any field to keep the value already in the real-time clock.  Application:  External clock can via [[Time_synchronization#Close_contact|RCI synchronize]] AlphaCom’s HH:MM setting once per day without changing the other fields.
+
|align=center|1||[[CLOCK]]||colspan="3"|Date and time<br />[[AMC]] 08.01:  Use the value 0xFF in any field to keep the value already in the real-time clock.  Application:  External clock can via [[Time_synchronization#Close_contact|RCI synchronize]] AlphaCom’s HH:MM setting once per day without changing the other fields.
 
|-
 
|-
 
|colspan="2"|Response:||colspan="3"|[[SYSTEM_TIME]]
 
|colspan="2"|Response:||colspan="3"|[[SYSTEM_TIME]]

Revision as of 11:03, 8 March 2016

SET_SYSTEM_TIME 0x0027 39 AMC 05.00
$SST W1999 U12 U31 U23 U59 U59
$SST FFFF FF FF U03 U02 FF
Set a device’s internal clock to the given date and time.
1 CLOCK Date and time
AMC 08.01: Use the value 0xFF in any field to keep the value already in the real-time clock. Application: External clock can via RCI synchronize AlphaCom’s HH:MM setting once per day without changing the other fields.
Response: SYSTEM_TIME

See also: AlphaCom clock

Back to AlphaNet message list