Actions

Difference between revisions of "SCAN RCI ONCE"

From Zenitel Wiki

(New page: {| border="1" align=left |- !style="background:#ffdead;" width="90pt" colspan="2"|SCAN_RCI_ONCE !style="background:#ffdead;" width="100pt"|0x0020 !style="background:#ffdead;" width="30pt"...)
 
Line 1: Line 1:
{| border="1" align=left
+
{| border="1"
 
|-
 
|-
 
!style="background:#ffdead;" width="90pt" colspan="2"|SCAN_RCI_ONCE
 
!style="background:#ffdead;" width="90pt" colspan="2"|SCAN_RCI_ONCE
Line 20: Line 20:
 
|-
 
|-
 
|}
 
|}
 +
 +
 +
[[AlphaNet_Data_Protocol#RIO_Protocol|Back to AlphaNet message list]]

Revision as of 11:50, 17 July 2007

SCAN_RCI_ONCE 0x0020 32 AMC 05.00
$SCAN W1 U3 U5
Scan input until defined condition is met, then report to exchange.
1 UINT2 Input pin number
2 UINT1 Scan mode: <br\>0 = Stop scan <br\>1 = Report when input is off <br\>2 = Report when input is on <br\>3 = Report when input changes (both on and off)
3 UINT1 Stabilization time. Unit = 10ms.
Response: SCAN_RCI_ACK