Actions

Physical number 5 and 6 (AlphaCom E7): Difference between revisions

From Zenitel Wiki

No edit summary
No edit summary
Line 1: Line 1:
In the AlphaCVom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.  
In the AlphaCVom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.  
* To set physical number 5 and/or 6 to be used as program distribution inputs on line c-d when an ASLT board is placed in board pos. 1:
:* The jumpers P5 and P6 are set to pos 2-3.
:* The potmeters P5 and P6 are used to adjust the input level.


* To set physical number 5 and/or 6 to be used as normal subscriber ports:
* To set physical number 5 and/or 6 to be used as normal subscriber ports:

Revision as of 08:43, 13 August 2009

In the AlphaCVom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.

  • To set physical number 5 and/or 6 to be used as normal subscriber ports:
  • Set jumpers 5 and 6 to pos 1-2
  • In AlphaPro, select Exchange & System -> Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange