Revision as of 18:13, 12 November 2007
Event description
Event Owner: | A station or UDP group |
Event type: | 15 - Event trigger feature |
Subevent: | See below |
When change to ON: | When dialing a dirno with feat. 52, 85, 95 or 105 |
When change to OFF: | When feature 95 or 105 disconnects |
When related to: | The event trigger directory number |
Event triggers
- - Feature 52 (9534): Event trigger without cancel tone
- - Feature 85 (9533): Event trigger with cancel tone
- - Feature 95 (9535): Event trigger with directory number parameter
- - Feature 105 (9545): Event trigger with digit parameter
Subevents
- - Default = 0. Possible to use param1 for feature 52 and 85. This can be used to group event triggers by filtering on subevent type.
Additional information
- - Feature 52 and 85 only triggers the ON event
Application
- - Any function or combination of functions which is not supported by the standard features in the AlphaCom