The IND (INDication) action is used in the [[Event Handler]] for sending commands to a station. The commands are sent as display data. The following stations are currently using the IND command: | The IND (INDication) action is used in the [[Event Handler]] for sending commands to a station. The commands are sent as display data. The following stations are currently using the IND command: | ||
− | * [[ | + | * [[IP Flush Master - 1008031000|CRM V]]: Control the LED's in the DAK keys |
* [[Control Room Master IV|CRM IV]]: Control the LED's in the DAK keys, the internal buzzer or relay, and the backlight of the display | * [[Control Room Master IV|CRM IV]]: Control the LED's in the DAK keys, the internal buzzer or relay, and the backlight of the display | ||
* [[Dual Display Station - 1007007000|DualDisplay station]]: Control the video-state of the DAK-display | * [[Dual Display Station - 1007007000|DualDisplay station]]: Control the video-state of the DAK-display |
Revision as of 07:51, 28 June 2010
The IND (INDication) action is used in the Event Handler for sending commands to a station. The commands are sent as display data. The following stations are currently using the IND command:
- CRM V: Control the LED's in the DAK keys
- CRM IV: Control the LED's in the DAK keys, the internal buzzer or relay, and the backlight of the display
- DualDisplay station: Control the video-state of the DAK-display
- Priscom station: Control the outputs used for lamps, cell light, call LED and spare output
Command syntax
IND <station phys.no> <output> <LED no/buzzer> <Ind-type> [state]
Between the command parameters, there must always be a space.
Parameter description:
Station/Parameter | phys.no | output | LED no/buzzer | IND-type | [state] |
---|---|---|---|---|---|
CRM V | Physical number 1 - 552 |
1-100 = DAK-key number | 1 = Red LED 2 = Green LED |
1 = continuous (low priority) 2 = slow flash (medium priority) |
ON or OFF |
CRM IV | Physical number 1 - 552 |
1-100 = DAK-key number 1023 = Buzzer 1024 = Display backlight |
DAK-key:
Buzzer:
Display backlight:
|
DAK LED's:
Buzzers:
Display backlight:
|
ON or OFF |
DualDisplay | Physical number 1 - 552 |
1-100 = The DAK-key line | Always "1" | Video-state of the DAK-display:
|
ON or OFF |
PrisCom | Physical number 1 - 552 |
1 - 4 = Lamp outputs 5 - 6 = Spare outputs 7 = Cell light 8 = Call LED |
Always "1" | Output state:
|
ON or OFF |
The state parameter is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.
Example
IND 2 23 2 3 ON = Station 2, key 23, turn green led, fast flashing, ON